Voron homing override

Unless you change modes G90 or G91, the printer stays in the last mode it was in. I use 100 - with 75 it crashes a bit into the frame and with 125 it does not home. Be aware I see my config as WIP and it can and will change any time. Also, as the Klipper docs instruct, set the homing_retract_dist to 0, and make sure your X and Y homing_speed values are set to half of your rotation_distance (homing_speed should be 20 for Vorons with 20T pulleys on the A/B motors). Starts printing when Z is at 30. Set min/max mesh points accordingly (mesh_min: 25, 25 and mesh_max Jan 24, 2024 · Hello, I am getting so close, the X and Y axis seems to be homing fine but the Z keeps saying out of range 10. GitHub Gist: instantly share code, notes, and snippets. Make sure you update to the latest klicky-macros. Be careful not to go too low! variable_brush_start: 234 variable_brush_width: 36 variable_clearance_z: 5 ; When traveling, but not cleaning, the clearance along the z-axis between nozzle and brush. Nov 4, 2023 · The BED gets much better leveling numbers now. Take that homing gcode you tried to use. cfg and change it there. probe确认. 57 lines (43 loc) · 1. Apr 27, 2024 · Well, in prepration to install a Canbus toolhead, I decided to switch to sensorless homing. [gcode_macro HOMING_OVERRIDE_X] gcode: RESPOND PREFIX="info" MSG="Homing > X". Never had this issue. cfg内[homing_override]宏,在做z归零前要先detach_probe,否则如果挂着probe做z归零,那么将是probe而不是喷嘴碰到z终端。 由于xy偏移没有了,所以bed mesh与qgl的坐标都可以视情况做一些调整。 Dec 30, 2022 · More commonly I'm seeing a crash as soon as it tries to LOWER the gantry. Please help. Jan 22, 2023 · General Discussion. configfile. The issue with printer. # configurations for the logo and nozzle here. By doing so you will be able to automatically start a heatsoak and customize your printer's behaviour. For each axis you can create a macro named "HOMING_OVERRIDE_<axis_name>" like below. Community Submission Information. only later i found out that there is need for homing_override described in other section Apr 5, 2018 · Interesting. You can't use rename_existing with G28, you need to use homing_override. md at work-annex-probe · cloakedcode/klipper · GitHub WARNING: The safe_z_position option is no longer used, please use the standard homing mechanisms if that functionality is required (i. One rotation moves the bed 4mm. These are exactly the same as what is in safe_z_home. G28 Y. The next step is tuning the your sensorless homing setup, please read this guide. 4957. That way when going to 0 it would have tried to move the nozzle to -25mm. Pasting your printer. Changed Z endstop to virtual. whereas is should be at 119. However the homing override method always homes X and Y before homing Z. It may even be possible to do this with the recently posted Z_TILT_ADJUST demo code and some homing_override directives. 000mm. problem was that if home few times in row, printer starts grinding it self. In addition, make sure the Y_DIAG jumper is installed on the SKR. cfg. 000 -3. Set min/max mesh points accordingly (mesh_min: 25, 25 and mesh_max By default, all printers are setup with a [homing_override] configuration section that includes a gcode macro for the home process. This is the config of my Voron 2. 4s. cfg: Aug 29, 2023 · Voron 0. Certain settings in this file override their counterparts in skr-pico. Any advise on what to do/modify to make them play well/work together? Apr 28, 2023 · Increase your 3d printer's reliability and durability with these step by step instructions that show how to use Sensorless homing to eliminate microswitch en Feb 17, 2020 · They essentially are capable of the same thing, the difference being that safe_z_home is specifically targeted toward homing Z and homing override can be used for all axes. safe_z_home, homing_override May 31, 2021 · Published May 31, 2021. In the one where it's grinding, that Apr 6, 2020 · Step 8 Gantry Corners. log file. Contribute to rpanfili/voron-ht development by creating an account on GitHub. He has never built a Voron, but owns a couple of 2. Dec 6, 2023 · Added new variable for homing Z where it allows you to back off the Y axis after Z homing for use with sensorless homing systems where the axis will need some travel room to home, especially if the machine is restarted with the toolhead directly above the Z endstop switch at the very back of the printer. found out it doesnt matter really i changed it to [homing_override] gcode: G28 Z0 G28 X0 G28 Y0 G1 Y10 F600 G1 X10 F600 G1 Z280 F600. I use a 1mm lift after homing, but you can change it to 5mm if you prefer. I would not do this but instead use [homing_override] as you then can simply call a standard G28 Z. Posted December 22, 2022. Aug 16, 2023 · I recently converted one of my Voron 2. Stable Z Homing for Klipper Note: due to recent events, various technical shortcomings with Voron printers, and inappropriate and irrational actions taken by the Voron team against a substantial number of dissenting community members expressing their right to free speech, including myself, I no longer recommend building printers of their design. BL Touch) as a virtual Z Endstop, instead of a microswitch located on the frame somewhere. Jun 23, 2021 · hi guys. So if I don't have a fully functional config file, the printer won't boot. i was thinking that the values would changes allot when i did bed leveling but the config is just recalculating position according to what the bed leveling is wich is very neat Dec 21, 2023 · The homing video and it doesn't look ok to me. This site uses Just the Docs, a documentation theme for Jekyll. 000 figures. There is also no functional Endstops, because I used sensorless Homing. . # To override settings from this file, you can copy and paste the relevant # sections into your printer. Therefore it is included after those files. However. You can reach me on the Voron Discord as Frix_x#0161. [homing_override] 轴: Z set_position_z: 0 gcode: G90 G0 Z15 F600 G28 X Y ## Z 限位开关的 XY 位置 ##通过后将X0和Y0更新为你的值(如X157、Y305) ## Z 轴限位位置定义 G0 X206 Y300 F3600 A guide to useful VORONklipper presets. That means that in general any macro or override you have in your This document aims to help you get a better, simpler and more powerful print_start macro for your Voron printer. config, and restart the host software. Link down be Feb 11, 2023 · Basic Information: Voron 2. I've created a new test branch ( work-homing-override-20180116 ) that will allow one to define a series of g-code commands to run in place of G28 commands found in the normal input stream. gcode: {% set home_all = 'X' not in params and 'Y' not in params and 'Z' not in params %} {% if home_all or 'X' in params %} May 27, 2024 · If you use the Klicky probe, then you already have a [homing_override] section. There is a macro near the end of that guide that you can use to temporarily define the driver parameters for homing only, then back the motor off a little. dir_pin: PE10 #方向控制引脚(方向错误请在PE10前加!. Those thinking about going with the TAP should think again! Remove that last line (G0 Z5 F500) from your [homing_override], and set your start gcode in Cura to something like this: G28 ;Home Axis G90 ;absolute positioning G92 E0 ; set extruder to zero G1 Z1 ;Move nozzle up, then proceed to print . So I’m building my first Voron the 2. 4 350mm3 Serial:V2. 000]" Apr 30, 2023 · Apr 30, 2023. -If Yes, proceed; if No, home X-Axis. gcode: Sep 27, 2022 · I’ve been reworking mental’s PR for a dockable_probe and would like to invite feedback! Hopefully this is a good place for it. I started out with github sample, but tried to add sensorless homing. It's activated by a new [homing_override] config section - see config/example-extras. Update your Z homing position: If you use [safe_z_home], change the location to the center of the bed. For the Voron Switchwire, these are the recommended configuration on the klicky-variables. Microswitch probe with magnetic attachment, primarily aimed at CoreXY 3d printers. I was using Klicky, and the dock kept being off by a little. Voron 2. G28 X. You switched accounts on another tab or window. Tips for sensorless homing on CoreXY¶ It is possible to use sensorless homing on the X and Y carriages of a CoreXY printer. 000]. ) Run a BED_MESH_CALIBRATE. Voron Documentation on GitHub. This would be a method at the end of print to turn off the motors then re-enable them at will later on, the flags that consider them homed do not get cleared. Printers go brrrrrrrrrrrrr. The following pin examples are from a BTT E3 mini V2; make sure to adjust based on your own Mar 7, 2019 · I need to lift Z before homing X, Y or Z. 4 MCU / stm32f446xx klippy. If you have a [homing_override] make sure that it moves the toolhead to the center of the bed before calling G28 Z. If you want a quick way to get around this. PA3. It is a much more complex build because it includes things such as 4-point gantry tramming to align to the print surface, more stepper motors and other unique features. If I change the Homing override to X220 it will Home right in the middle. Set your driver_sgthrs to 64. I haven't run across that myself, so I don't have a ready answer. Modifiy your printer. at least all my Vorons V2. axes info and just print out the command. See Voron Klipper for details. There are a number of NeoPixel macros that can be added to give you different types of control over them and are usually pretty safe to run. ldo_macros. So if the bed isn't perfectly level the Z height is This is the standalone repository of the Klipper LED Effects module developed by Paul McGowan with contributions from myself. 2. ## if your fan will not start. cfg, and then you can skip the rest of this guide; you're done here! Klipper configuration for my Voron 2. My problem is I am not able to get the bed at proper print height. Note that if the driver current during homing is changed, then the tuning process should be run again. cfg file to modify homing which I believe interferes/overlaps with your macros. How can I do that? Configuration: [homing_override] axes: xyz. When setting up sensorless homing it was required to create a homing. Jan 2, 2023 · I implemented the homing_override like stated in the documentation for sensorless homing but I can't get Tap to home z in the middle of the build plate. Today, my last task before the first print was to calibrate the extruder. 5A. When I start a print, it heats as expected and when it comes to start the print it fails with: "Move out of range: -0. You can see Y is moving slightly during the X home. Measure the nearest stepper to this corner, and use negative X and Y values for this corner. 660 - klipper_config/homing. 5 AMP BY . So i tried to add two different homing_override for Z and XY. This method is much more accurate and has the advantage that the Z height can be determined in the centre of the bed. It works well, but I would like it to move the head up by some mm before trying to home, as the normal traditional homing does. Feb 7, 2024 · Quick question on the fan logic with a new LDO 2. cfg back to github sample. Not to G28 or QGL every time from start macro if its already done. Oct 5, 2021 · So I need to detect the homing state with {% if printer. Reload to refresh your session. mykepredko January 31, 2023, 9:08am 3. If its already done, skip it and continue, this can save some time since the TAP needs to cool off, etc for this. Make sure you have the latest klicky-macros. Blame. Then homes as usual. Voron History. Skip to content. Aug 30, 2023 · I spent all afternoon trying to get the X and Y working for sensorless homing and it seems like I got it to work with SGTHRS values of 75 and 65 respectively for both X and Y however, after the TAP wire was installed and some of the configs for TAP were done, my X and Y sensorless homing no longer seems to work. Add a comment. Navigation Menu # Homing Override [homing_override] axes: xyz. 94 KB. axes existed. X. Cannot retrieve latest commit at this time. 4R2 350 configuration. Aug 31, 2022 · Almost there with my settings, I am now trying to find a “non macro” solution to this issue: I am using sensorless homing, so homing_retract_dist is not an option, now, when Homing XY or Homing All, I would like the X axis to move by 10-15mm after “hitting” the virtual endstop, to prevent him of flirting with the Z axis rods and ledscrew support when travelling his way to home Y. Or just wait 2 days and save a few headaches and a lot of frustration trying to force Klicky Probe Homing issue. I tried to add G92 and 91 but it still wants to home before accepting any move command, any idea? -- [homing_override] axes: xyz gcode: Apr 23, 2023 · Voron V2. # WARNING. May 11, 2018 · SET_STEPPER_ENABLED STEPPER=stepper_x ENABLE=0. Voron StealthBurner LEDs config example. Jan 17, 2023 · Basic Information: Printer Model: voron 2. SKR mini E3 v2. DO NOT EDIT THIS FILE. cfg file for the VORON2 printer and matches the manual/build guide exactly # for controllers used (dual RAMPS) and pin layout for all connected components. I ended up re-tuning the sensorless homing it if fixed this issue. Update your probe's offsets: The last piece to bring everything together is [homing_override]. ¶ Auto-generated Configs If unenclosed, heat the bed and let it sit for a few minutes. QGL and mesh use Klicky Probe. Apr 6, 2023 · How to set the homing to the corner you want sensorless-homing. cfg: ## Controller fan - FAN2. Read on to learn all about the G28 command! The resulting macro can be called from a homing_override config section or from a START_PRINT macro. -Raise Z-Axis 5mm. But there is definitely something amiss that is connecting X movement to a bit of Y movement. variable_z_endstop_y: The Y position of your Z-endstop pin. Sensorless homing is a Klipper feature where it moves the carriage and bed until they hit the frame of the printer. Feb 5, 2023 · Firstly, You had the [probe] section defined twice and though the z_offset is defined under the first [probe] heading, klipper read the second [probe] heading as well (the one you put the code for the TAP) and could not find the Z-Offset. TMC 'stepper_z' reports error: GSTAT: 00000001 reset=1 (Reset) Once the underlying issue is corrected, use the. G1 Z10 F600. running Calibrate_Z tests the difference between nozzle plunge and Klicky switch plunge on the endstop. May 5, 2024 · You’ll need to switch to homing override. 4's over to full canbus with sensorless homing. 将工具头置于床身中央,再次确认探头工作正常。 离床较远时,QUERY_PROBE应返回“开”。 Overriding individual axis homing. SET_STEPPER_ENABLED STEPPER=stepper_y ENABLE=0. # The name of the addressable LED chain that contains the nozzle LED (s). 2 Z woes I have got x and y working perfectly with sensorless homing. With this macro you will be able to pass variables such as print temps and chamber temps to your print_start macro. 4 350's. SET_STEPPER_ENABLED STEPPER=stepper_z ENABLE=0. "FIRMWARE_RESTART" command to reset the firmware, reload the. Currently defaulted to be a lot higher for safety. Homing uses z endstop pin. Overrides are tuned versions of standard klipper commands or actual overrides of gcode commands that should probably be like this by default (at least for VORON printers). # For other build sizes, controllers, or non Hey guy! Its Jprince (GoldenJaguar392)In Today's video I am going to show you how to configure the klicky probe in klipper firmware basic setup. cfg and picobilical. The first four stages are similar to what Z_TILT_ADJUST does. It will do the same thing. fan_speed: 0. Accuracy is not so much a problem because I use Tap. You signed out in another tab or window. Voron Official and Community Documentation. I tried this, but only the second is applied : [homing_override] set_position_z: 10. # We have attempetd indicate those in the comments throughout the example code. # Z elevation is shown in movements to ensure adequate Z elevation to avoid crashes. VoronDesign Home. homed_axes != ‘XYZ’ %} and make a Z move off the mechanical stop, then G28. #4. 4r2 build: There is this section in Klipper's printer. This depends on your printer. # To use this config, the firmware should be compiled for the STM32F446. May 22, 2024 · You can change the status colors and led. config and printer. Since my z probe is offset from the nozzle, I need z homing to go to the middle of the bed before homing. Reply reply More replies More replies JohnHue Code. Pull Request Guide. Jan 25, 2023 · Cooling Type. If you've got an endstop on y, steal it, set y up for sensorless homing and use that endstop on z. This override allows us, the end user Apr 30, 2023 · Apr 30, 2023. Here are the relevant (I think) configs. Using the BTT Manta M8P MCU with the CB1 SBC, StealthBurner + Phaetus Rapido UHF PT1000, kinematic bed mounts, ultra-flat bed, titanium backer, keenovo fermio 750w b The macros and instructions on how to configure are located on the Macro directory, you need to check that before continuing on the build, there are also some RRF scripts that work for the Voron V2. 4 and might work for the switchwire also. Voron 2 . LOGIC: -Set G90. The G28 G-code command brings your machine's axes to their true zero position or home. cfg - This file contains a number of commonly used macros. I want to retain the stock z endstop and use it to automatically set the z offset to the nozzle so i included the klinky-config and z calibration. 4 with Spider 1. 3648. Where Jan 2, 2022 · homing_override and safe_z_homing cannot be used simultaneously. FYSETC is the sponsor of this build, and the board is great if setup properly. When I comment out the homing override, x and y home just fine. homed_axes != ‘XYZ’ %}. 660. 2 on VORON 2. 4 with a raspberry pi 4 2gig, octopus board, I managed to test all motors and successfully homed X and Y Mar 30, 2023 · Reduce your run_current when homing to 0. Feb 23, 2023 · i just build voron 0. I have a homing override macro, copied almost entirely from the voron documentation. Here are the docs: klipper/Dockable_Probe. 000 0. By default, all printers are setup with a [homing_override] configuration section that includes a gcode macro for the home process. This macro is updating during the setup process to define the Z endstop location. Yes, it does. If I could jog the Z during not homed status with a macro it would work. Run all homing/leveling routines (such as G28, G32, QUAD_GANTRY_LEVEL, and Z_TILT_ADJUST. Use G1 X0 Y0 Z20 to move to the opposite corner. The above homing_override would move z up 10mm, Home Y, Home X, Move to X85 Y73, then home Z. So here’s the deal, up until yesterday, I’ve tun stepper buzz and adjusted the motors, ran homing sequences, QGL, PID and even bed mesh. Sometimes 0. 4 (Formbot kit). Dec 26, 2022 · Dec 27, 2022. Usually less than 0. 002mm variation. Homing works in hot and cold state (when hot bed 110, nozzle 240, chamber temp about 50C ) BUT. You signed in with another tab or window. Code. V2. I am wondering, there seems to only be a way of setting the Z speed during a G28, all about that here: But what about the X and Y speed, I find the default speed to be sooooo annoying (GOM yes) since its a speed where printers resonate on. 4, V1. G1 X85 Y73 F9000. While Homing the Z and Y Axis Home properly, but the Axis thinks that Position 0 is 110. Z also works perfectly. I've got to the point of commenting out safe_z_home and adding the include for klicky-probe. # VORON2 250mm config # This is a base printer. NoGuru said: Yep, and don't forget to tune them for sensitivity. If I was doing both printer. ## Z Endstop Switch location [homing_override] section ## Z Endstop Switch offset Other Resources. Reduce your homing_speed to 25. The stepper driver senses those lost steps which Klipper can then use to know that it has hit the end of the axis. # tune this once it's working. cfg with the following code to enable sensorless homing:. Yes, if you're using homing override you're expected to do your own Z-homing, so you have to disable safe homing. Before that, I decided to tidy up the wires on the bottom Jan 31, 2023 · The issue with the single Z may be due to you overriding G28. sensorless_homing. Before that, I decided to tidy up the wires on the bottom I'm trying to create a macro that will function for the Z-Axis homing_override and will only home the X and the Y Axes if they are not already homed. heater: heater_bed. If it crashes when reaching 0, add 10 to the value Configuration backup for my Voron 2. # typically be the same LED chain as the logo. 000] When I hit the Upload & Print button in Mainsail the printer goes through the regular routine of heating up the bed as well as the extruder. The main reason people use a Safe Homing position is when they're using a Probe (e. cfg and instead use the one provided by VORONklipper: variable_z_endstop_x: The X position of your Z-endstop pin. 2 and we have not received other vendor's items to conform our firmware to them also. cfg is not needed When pasting code or config snippets use the code tags </> in the menu above Describe your issue: HI, I now use Klicky instead of the original proximity switch, so in the configuration homing_override replaces Apr 20, 2023 · I just finished building my new 350x350 Voron 2. 2, and started initial setup,documentation is nice, it even explains how to tune sensorless homing. Finally the build is complete but sadly still running Marlin at this point. Alright, I managed to fix the mistake. Nov 26, 2018 · I can't seem to get homing override to work. Which based on the Klipper config reference, "will be enabled when any of the given heaters/steppers are Corexy doesn't need anything unique that's not already in your config file. If you have a [safe_z_home] section, find it and comment it out as we will be using homing override as found in homing. Stepper Config: [stepper_z] step_pin: PB13 dir_pin: PB12 enable_pin: !PB14 rotation_distance: 40 microsteps: 16 Jan 29, 2022 · Voron Trident 中文注释配置文件. # This file contains common pin mappings for the Fysetc Spider board. driver_SGTHRS: 120 # tune this once it's working. Did not work. Fun fact: "pain" \pɛ̃\ is the French word for bread, so there's no pain in this pain—only joy! Thanks to the French channel "honhonhonbaguette-FR" on the Voron Discord for the joke and name suggestion! Trident Homing Routine. pin: ^!. And replace g28 in your print start macro with it. log Fill out above information and in all cases attach your klippy. Searched the code in the printer config file but found nothign containing -10. g. I normally do only checkin stuff that is tested and run with the base klipper branch but I test also klipper PRs so it can happen that I oversee that from time to time and have stuff here that needs a special PR from klipper. 000 4. 0 - bistory/voron-2. 8, Trident, V0) and derivatives, now it's been restructured to better allow other printers to be documented here. Since klipper loads and applies the config from top to bottom. G28 Z. This will. I've tried several things like just enabling homing override for z (axes: z). Or if I could use the homing override along with Z safe home, but homing override only active with {% if printer. ##T8x4 Lead Screws. Config file (s) for SKR2 + TMC2130 + BLtouch + Sensorless Homing. I'm working on adding Klicky Probe. 5. Just set up and tune as per the link. If you use a stock config file from the voron repo or the Klicky probe, then you already have a [homing_override] section. If you’re running a CoreXY/Voron 2. settings branches then when the code hit the second branch it will already have the homing_override. Once you’ve done that, test the sensorless homing for the X & Y axis separately and determine the best driver_sgthrs by running the axis homing twice until it works reliably both times. Jun 11, 2023 · CANCEL_PRINT. 000 175. 11. 4 printer, you may want to add: homing_override (if you are using TMC2209 stepper drivers and doing sensorless homing) Instead of editing a homing_override section yourself, you can remove it from your printer. Jul 9, 2017 · KevinOConnor commented on Jan 16, 2018. cfg Jan 21, 2022 · 修改homing. For TMC2209 . Other than that, it works the same way as a limit switch. Took the printer to a friend's house. 4 MCU / Printerboard: klippy. toolhead. 707. 4. The Voron V2 is a modified CoreXY design with a static bed and a gantry that moves along the Z axis. 000 [0. e. Homing Override / Safe Z Home . I have a copy of my script below but it still keeps homing them regardless of the logic. So when it is working, the last mode the printer was in was G90 when it crashes it was in G91 and would have gone out of bounds. I used the first homing_override until today (capacitive probe), but now i want that the nozzle move Z+15 when G28 X0 Y0. Only changes made were run current, which I calculated by 1. In the printer’s web interface, click the “Tuning” tab (Fluidd) or “Heightmap” tab (Mainsail) on the left. 302 lines (271 loc) · 7. 4, there are some subltle things to change. Aug 8, 2023 · Changed the printer. Measure from the homed X and Y to the closest stepper motor, use that X and Y as one Gantry Corner. kick_start_time: 0. # Created by "Boff" with help from the VORON community. Initially it was focused on the Voron printers (V2. It allows Klipper to run effects and animations on addressable LEDs, such as Neopixels, WS2812 or SK6812. variable_wipe_qty: 5 ; Number of complete (A complete wipe: left, right, left OR right, left Nov 18, 2022 · To solve the problem I had to save the command in namespace and print the command out at the end if homing_override. Klippain is regularly updated with new features and merged PRs from users. Read on to learn all about the G28 command! Advertisement. homed_axes I have no idea but it could very well be linked to the point above. So I want to see if its possible to check the status of G28 and QGL if its already done in previous print for example. Aug 12, 2021 · 使用这些值更新[homing_override]或[safe_z_home]下打印机配置文件中的归位路由。 重新启动 Klipper FIRMWARE_RESTART。 运行完整G28并确保打印机正确定位 X、Y 和 Z。 7. 4; make sure to get the needed MACROS as well! FYI: The voron project below is only supporting with FYSETC Spider v2. Oh and bed mesh is a rocket compared to TAP since it never touches the BED. Once that happens, the stepper motor loses steps. log Describe your issue: Hi All, I’m getting this error: Move out of range: 209. When I restart and try to home, it homes X, then Y, and then Nov 7, 2023 · # For moving gantry sytem like Voron 2. cfg - This contains settings to implement sensorless homing on the Voron0. 000 10. 200 [0. . 010m with TAP. [controller_fan controller_fan] pin: PD12. Everything I tried results in a timeout while homing x. -Check if X-Axis Homed. I'm curious about the Voron 2 homing procedure. #2. Contribute to VoronDesign/Voron-1 development by creating an account on GitHub. cfg at master · zellneralex/klipper_config I have my Switchwire conversion running. cfg on the new branch for details. We would like to show you a description here but the site won’t allow us. Dec 22, 2022 · My Voron Family: V2. In the videos of moving X you can see Y is moving. History. You can use force move for testing purposes, I don't think Klipper will let you print without homing and won't home without a z stop or probe as far as I know. cfg for the FYSETC 2. 1 KB. Below is the new printer. He said it worked. Never got less than . It doesn't sound that difficult to script this up in Klipper (it can be done entirely in the Python code). Dec 26, 2021 · This is the config of my Voron 2. cfg, and then you can skip the rest of this guide; you're done now! If you already have a [homing_override] and you're not using Klicky, replace calls to G28 X with _HOME_X and replace G28 Y with _HOME_Y. The problem is I had everything automated, including power. Each gcode must contain G990028 X0 gcode command - replace X with the axis you're overriding. When trying to move to 0 the machine already used the y-offset of the Klicky probe. I needed to adjust my min/max mesh points in the printer. The only variables I have adjusted are: To match where my endstop is. The [homing_override] block we have in the above macros is now going to be responsible for all homing, whether via the buttons in Mainsail or Fluidd, or via commands like G28 X, etc. zl vh bx fn yu bm cu ev vj bv